RSS-160-S Vacuum Reflow Solder System

Unitemp Germany SKU: RSS-160-S
Your inquiry was submitted successfully. You can expect to hear from us shortly.

The RSS-160-S Reflow Solder System is a very compact and easy useable tool for the use in laboratories and clean rooms as table top unit. The chamber is vacuum sealed and equipped with a viewing window. This allows the view control of the soldering process. The unit is equipped with a Mass Flow Controller as standard for the process gas.

The reflow solder system is perfect for the following applications:

  • flux-less soldering
  • flip chip process
  • adhesive bonding
  • solder bump reflowing
  • encapsulation of housings
  • soldering of power devices
  • heat treatment of semiconductor wafers
  • prototype development
  • quality control

 Technical Data:

  • heated area: 160 mm x 160 mm (= model RSS-110-S)
  • chamber height: 40 mm (optional up to 80 mm)
  • viewing window with 60 mm dia.
  • Mass Flow controller for Nitrogen (5 nlm)
  • vacuum atmosphere up to 10exp.-3 hPa (KF16 connector)
  • temperature up to 400 °C (optional up to 500 °C)
  • ramp up rate:      better 100 K/minute
  • ramp down rate:  better 100 K/minute
  • SIMATIC© process control with 50 programs and 50 steps each
  • 7" touch panel
  • water cooled chamber (controlled and watched)
  • electrical connection type: 230V, 2.4 kW or 115V, 1.2 kW

    Datasheet Download

    Model RSS-Series (RSS-110-S, RSS-160-S & RSS-210-S)
    Reflow Solder Systems & Ovens Model Comparision 

     

    Options and accessories

    FA I Formic acid module (separate module, not integrated) with Mass Flow Controller
    FA II integrated formic acid module with Mass Flow Controller
    FA III integrated formic acid module with shared Mass Flow Controller
    MFC additional Mass Flow Controller (max. 2 pcs)
    RSS-EH Chamber height 80mm instead of 40mm
    RSS-H2 Hydrogen Module: for using 100% Hydrogen incl. gas line with Mass Flow Controller
    RSS-H2S Safety device to prevent uncontrolled emission of Hydrogen
    RSS-IL Interlock mechanism during operation
    RSS-TC Additional thermocouple (max. 2 pc)
    VAC I Basic Vacuum up to 3 hPa, incl. vacuum sensor and valve, excl. pump
    VAC II Comfort Vacuum up to 10E-3 hPa, incl, vacuum sensor and valve, excl. pump
    MP Membrane/Diaphagm pump for vacuum up to 3 hPa
    MPC Chemical resistant membrane pump for vacuum up to 3 hPa
    RVP Rotary vane pump for vacuum up to 10E-3 hPa with oilfilter
    WC I Closed loop water cooling system