HYGIENIC STEEL SENSOR FLUSH DIAPHRAGM_PSM-2 Pressure transmitter-Nano Vacuum Australia and New Zealand

HYGIENIC STEEL SENSOR FLUSH DIAPHRAGM_PSM-2 Pressure transmitter

SENS4 SKU: PSM-2
Your inquiry was submitted successfully. You can expect to hear from us shortly.

Programmable precision pressure transmitters with hygienic diaphragm sensor

PSM-2 Pressure transmitter

  • Measurement range 1-35 bar absolute and gauge
  • All welded flush steel diaphragm pressure sensor
  • 4-20 mA, 0-10 VDC and setpoint switch output
  • Programmable settings and configuration with S4-Connect™
  • Hygienic 316 stainless steel design

ADVANTAGES 

  • Chemical and corrosion resistant 316 stainless steel diaphragm
  • All-welded flush sensor design (No internal O-rings)
  • Integrated flange cooling section
  • High accuracy 0.1% of span (BFSL)
  • USB programmer for easy configuration and setup
  • Temperature drift compensated
  • Configurable with S4-Connect USB programmer
  • Robust 316 stainless-steel design
  • IP67 enclosure for harsh environments
  • Optional solid-state setpoint relay for process control

The PSM-2 series programmable pressure transmitter is designed for gas, vapor and liquid measurement in pharmaceutical, food, beverage, and biotechnology applications.  The transmitter is compatible with the temperature and chemical exposure used in industrial standard CIP (Clean-in-place) and SIP (Steam-in-place) cleaning processes. 

The PSM-2 is programmable and configurable from PC via the novel S4-Connect™ interface.

 

Sensor technology

The PSM-2 is based on a stainless steel 316L diaphragm that converts the applied pressure to an electric signal. The sensor diaphragm is flush with the flange and has a surface roughness RA value of less than 0.38 µm. The flush sensor diaphragm enables use in applications with pressure media with high viscosity that can clog small sensor cavities. The sensor element uses an internal FDA approved filling fluid to transfer the pressure from the sensor diaphragm to the piezo sensor element. 

It is available either as an absolute sensor that measures relative to an integrated sealed reference vacuum or as a gauge sensor that measures relative to the ambient pressure.   

 

APPLICATIONS

  • Food and beverage processing
  • Sterilization processes SIP and CIP
  • Water treatment and supply
  • Chemical processing
  • Biotechnology
  • Hydrostatic level measurement

Download brochure here

 

PSM-2 PRESSURE TRANSMITTER SPECIFICATIONS

Specifications


Measuring range (0 bar to full-scale)
1, 1.6, 2, 2.5, 4, 5, 6, 10, 16, 20, 25 or 35 bar
Measuring range (0 bar to full-scale)
15, 20, 30, 50, 100, 200, 250 or 500 psi   
Measuring principle
Piezo with stainless steel membrane absolute
Accuracy, IEC 61298-2
+/- 0.1 % BFSL
Thermal drift (offset)
+/- 0.15% of full-scale
Output signal (Voltage version)
0-10 VDC (Programmable scaling by S4-Connect™)
Output resolution (Voltage version)
16 bit / 150 nV
Output signal (Current version)
4-20 mA(1) (Programmable scaling by S4-Connect™)
Output resolution (Current version)
16 bit / 244 nA
Solid state relay contact rating (optional)
250 mA, 50 VDC / VAC peak

Environment conditions


Operating ambient temperature
-40 to +100 °C (-40 to +212 °F)
Media temperature
-50 to +150 °C (-58 to 302 °F)
Storage ambient temperature
-40 to +125 °C  (-40 to +257 °F)
Maximum media pressure
See PSM-2 pressure limits specifications
Burst media pressure
See PSM-2 pressure limits specifications
Mounting position
Any
Protection rating, EN 60529/A2:2013
IP67 (2), IP65 (3)
Humidity, IEC 68-2-38
98%, non-condensing

Power supply


Supply voltage 
12-30 VDC
Power consumption (Voltage version)
240 mW (Max)
Power consumption (Current version)
600 mW (Max)
Reverse polarity protection
Yes
Overvoltage protection
Yes
Internal fuse
100 mA (Thermal recoverable)

Materials


Enclosure
SS 1.4404 / AISI 316
Electrical connector DIN 175301-803A
PA Nylon
Electrical connector M12 IEC 61076-2-101
PA Nylon, Nickel plated Zinc alloy
Process connection
SS 1.4404 / AISI 316L
Process leak tightness (ISO 27895:2009)
<1·10-9 mbar·l/sec.

Approvals


CE
EN61000-6-2, EN 61000-6-3Pressure directive 97/23/CE
RoHS compliance
Directive EU 2015/863